CEMS-PRE225HSP- Heated sampling probe

CEMS-PRE225HSP- Heated sampling probe

Discover the CEMS-PRE225HSP heated sampling probe – ideal for accurate gas sampling in high-temperature, high-dust environments. Perfect for CEMS applications in power, waste, and heavy industries.

CEMS-PRE225HSP – The Optimal Heated Sampling Probe for Reliable Gas Monitoring

In industrial emission monitoring and environmental compliance, accuracy, durability, and reliability are critical. That’s where the CEMS-PRE225HSP heated sampling probe comes into play. Designed for extreme combustion environments, this probe is the ideal solution for continuous emission monitoring systems (CEMS) in power plants, incinerators, chemical processing, and more.

Whether dealing with high temperatures, high dust loads, or corrosive gases, the CEMS-PRE225HSP offers a robust design, automatic maintenance features, and precision filtration, making it one of the most reliable sampling solutions in today’s market.

CEMS-PRE225HSP Heated Sampling Probe
CEMS-PRE225HSP Heated Sampling Probe

Key Features of CEMS-PRE225HSP

1. Advanced Temperature Control

The CEMS-PRE225HSP is equipped with an adjustable heating system ranging from 120°C to 180°C, which helps maintain a stable internal environment to prevent condensation and ensure accurate gas sampling. This wide heating range allows flexibility for different gas compositions and operating conditions.

2. High-Efficiency Filtration

Built with 2µm and 5µm stainless steel sintered filters, along with ceramic filtering options, the CEMS-PRE225HSP effectively removes particulates from sample gases before analysis. This ensures high purity of gas samples and protects downstream analyzers from contamination.

3. Automatic Blowback System

To minimize maintenance and extend service intervals, the CEMS-PRE225HSP integrates an automatic blowback system using clean, oil-free compressed air or nitrogen gas (0.4–0.8MPa). This function removes dust and debris from the filter element, maintaining consistent flow and performance.

4. Durable and Weather-Proof Design

With an IP65 protection rating, the sampling probe is fully resistant to dust and water ingress, making it suitable for outdoor or harsh industrial environments. Its corrosion-resistant materials ensure long-lasting durability under high-temperature and high-humidity conditions.

5. Flexible Installation

The probe is compatible with DN50 mounting flanges, allowing easy integration into a variety of exhaust systems. The modular design also allows customization to fit specific industrial needs or CEMS configurations.

Typical Applications

The CEMS-PRE225HSP heated sampling probe is ideal for a wide range of industries, including but not limited to:

  • Thermal power plants – For SO₂, NOx, and CO₂ emissions monitoring

  • Waste incineration – For VOCs and dioxin measurement

  • Cement manufacturing – In kiln and preheater exhaust analysis

  • Steel and metallurgy plants – For stack gas sampling under high dust and heat

  • Chemical and petrochemical sectors – For emission compliance and process optimization

Technical Specifications

Specification Details
Flue Gas Temperature Up to 180°C
Heating Temperature Range Adjustable from 120°C to 180°C
Filter Accuracy 2μm & 5μm (stainless steel sintering, ceramic)
Protection Level IP65
Mounting Flange DN50
Blowback Source Oil-free compressed air or N₂ gas (0.4–0.8 MPa)

Benefits of Choosing CEMS-PRE225HSP

  • Consistent Performance – Stable temperature control prevents sample degradation.

  • Low Maintenance – Automatic blowback reduces filter clogging and manual cleaning.

  • High Sample Purity – Effective filtration ensures accurate readings for compliance reporting.

  • Durability in Harsh Conditions – Built to perform in extreme industrial settings.

  • Customizable Design – Tailored to fit your specific CEMS system or industry application.


Why CEMS-PRE225HSP Is the Right Choice

When it comes to reliable and precise emission monitoring, choosing the right sampling probe can make a significant difference. The CEMS-PRE225HSP is more than just a component—it’s an integral part of your environmental compliance strategy. Its advanced engineering and smart features help you achieve consistent, accurate gas sampling while reducing maintenance efforts and operating costs.

CEMS-PRE100NOX- NOx Converter

CEMS-PRE422- Temperature Pressure Flow Integrated Analyzer for Emission Monitoring

CEMS-PRE400 Ultrasonic Flowmeter – Advanced Solution for Accurate Gas Flow Measurement

CEMS-PRE350 Heat Tracing Sampling Compound Pipe – The Ultimate Solution for Environmental Monitoring

CEMS-PRE100 Integrated Temperature and Pressure Transmitter